• 尊龙凯时[中国]官方网站

    Product catalog

    AD-III ​Infant/neonatal CPAP system

    Contact Us
    Online Message
    Detail

    Infant/neonatal CPAP system with medical air compressor

    CPAP continuous positive airway pressure system AD-III is based on positive pressure ventilation in the field of pediatric widely used noninvasive continuous positive airway designed for children with special medical respiratory support devices, premature children, newborns, infants and children up to 14 years of age CPAP ventilation treatment for children with nasal congestion . CPAP mode keeps children breathing spontaneously early, and can effectively reduce children's work of breathing.

    Features

    1.Treat in advance to reduce unnecessary tracheal intubation

    2.Shorten the time of mechanical ventilation

    3.Avoid excessive weaning

    4.Dual output interface, can expand oxygen therapy, resuscitation and BUBBLE CPAP

    5.Applied to neonates with mild respiratory failure with strong spontaneous breathing

    6.CPAP ventilation mode can reduce children's work of breathing while maintaining infant's spontaneous breathing. The positive end-expiratory pressure provided by CPAP helps collapsed alveoli to reopen, and has a good therapeutic effect on neonatal lung atrophy, lung trauma, hypoxic-ischemic injury and other diseases.

    7.Continuously provide constant flow and pressure-restricted CPAP mode for newborns and children .

    8.The external air and oxygen filter system can effectively remove the moisture in the gas.

    technical parameter:

    CPAP mode: a mode that continuously provides constant flow and pressure restriction for newborns and premature infants;

    Oxygen concentration adjustment: 21% ~ 100%

    Flow adjustment: 0 ~ 18LPM

    Continuous positive airway pressure ( CPAP ) adjustment: 0 ~ 1.0kPa (0 ~10 cmH2O)

    Alarming:

    Differential pressure alarm: The air supply pressure difference is greater than 0.1MPa, and the sound alarm;

    monitor:

    Pressure monitoring: 0 ~ 1kPa (0 ~ 10cmH2O)

    Oxygen concentration monitoring: 21% ~ 100%

    Pressure safety valve: When the pressure in the equipment pipeline exceeds 1.5 times the adjustment parameter , the safety valve opens automatically

    General parameters:

    Host size: W × H ×D 35.5cm ×14.5cm ×22.5cm

    Host weight: about 6KG

    Air supply: 0.3MPa ~ 0.4MPa.